EasyManua.ls Logo

Raven SmarTrax - User Manual

Default Icon
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
P/N 016-0171-277 Rev. L 03/18 E30676
Copyright 2009, 2010, 2011, 2012, 2013, 2017, 2018
SmarTrax™ Calibration and
Operation Manual

Table of Contents

Other manuals for Raven SmarTrax

Questions and Answers

  • N
    Natalie CarterSep 2, 2025
    What does 'No GPS' mean on Raven SmarTrax Farm Equipment and how do I fix it?
    • C
      Courtney BentonSep 2, 2025
      If you are getting a 'No GPS' error on your Raven Farm Equipment, verify the GPS receiver is properly installed and configured.
  • J
    Jeremy LeeSep 2, 2025
    What does 'Low Stats' mean on Raven Farm Equipment and how do I fix it?
    • C
      christophermillerSep 2, 2025
      If your Raven Farm Equipment is displaying 'Low Stats', it means the GPS receiver is not receiving signal from enough satellites. Wait a few minutes to see if more satellites are found.
  • J
    Juan MorenoSep 1, 2025
    What does 'High HDOP' mean on Raven SmarTrax Farm Equipment and how do I fix it?
    • A
      Ashley DavisSep 1, 2025
      If you are getting a 'High HDOP' error on your Raven Farm Equipment, it means insufficient GPS signal is being received. Wait a few minutes to see if the signal improves.
  • R
    ryanfisherSep 1, 2025
    What to do if Raven Farm Equipment SmarTrax will disengage only when the steering wheel is turned one way?
    • M
      Michael CostaSep 1, 2025
      If your Raven Farm Equipment SmarTrax will disengage only when the steering wheel is turned one way, replace the faulty flow disengage switch.
  • K
    Kimberly GrahamSep 1, 2025
    What does 'VALID POINTS LOW' mean on Raven SmarTrax and how can I fix it?
    • H
      hreidSep 1, 2025
      If you're experiencing a 'VALID POINTS LOW' error with your Raven Farm Equipment, verify that the SmarTrax hydraulic hose, fitting, and valve connections are secure and no leaks are present. Also, verify that harness cable connections are correct and securely installed and check the steering linkages to ensure they are connected securely and meet the machine manufacturer’s factory specifications.

Summary

Important Safety Information

Hydraulic Safety

Guidelines for working safely with the hydraulic system, including protective equipment and fluid handling.

Electrical Safety

Precautions for electrical connections, polarity, and voltage requirements for the SmarTrax system.

Introduction

Recommendations

Best practices for installing and operating the SmarTrax system for the first time.

Antenna Installation

Details on positioning the GPS antenna for optimal system performance and accuracy.

CR7 Calibration and Operation

Buttons and Definitions

Explains common status and mode information displayed on the CR7 during SmarTrax operation.

Machine Configuration

Steps for setting up machine profiles and configuring machine-specific settings in the CR7.

Calibrate SmarTrax System

Overview of the SmarTrax calibration wizard and initial setup steps for the system.

System Adjustments

Information on tuning system performance and adjusting parameters like Line Acquisition and Sensitivity.

Viper 4;4+ Calibration and Operation

Widget and Button Definitions

Defines common status icons and buttons used on the Viper 4/4+ display for SmarTrax.

GPS Configuration

Steps to configure GPS settings and ensure proper communication for the SmarTrax system.

Machine Configuration

Process for selecting machine types and setting up profiles for SmarTrax operation on Viper 4/4+.

Calibrate SmarTrax System

Detailed procedure for calibrating the SmarTrax system using the setup wizard.

System Adjustments

Guidelines for fine-tuning SmarTrax performance, including LA and OL modes.

Viper Pro Calibration and Operation

Software Compatibility

Requirements for Viper Pro software and SmarTrax node software versions for compatibility.

SmarTrax Status Display

How to interpret system status messages displayed on the Viper Pro screen.

Machine Configuration

Setting up machine profiles and specific configurations for SmarTrax on Viper Pro.

Calibrate SmarTrax System

Step-by-step guide to calibrating the SmarTrax system with the Viper Pro.

System Adjustments

Tuning SmarTrax parameters like LA and OL sensitivity for optimal field operation.

Envizio Pro and Cruizer II Calibration and Operation

Software Compatibility

Specifies required software versions for Envizio Pro/Cruizer II and SmarTrax node.

SmarTrax Status Display

Interpreting SmarTrax system status icons on the Envizio Pro/Cruizer II display.

Machine Configuration

Steps to configure machine profiles and specific settings for SmarTrax with Envizio Pro/Cruizer II.

Calibrate SmarTrax System

Guide for calibrating the SmarTrax system when used with Envizio Pro or Cruizer II.

System Adjustments

Adjusting SmarTrax settings like LA and OL sensitivity for optimal field operation.

Troubleshooting

Node

Explains SmarTrax CAN control node LEDs for diagnosing system issues.

Error Messages

Lists common SmarTrax error messages, their causes, and corrective actions.

System Diagrams

SmarTrax 3 D with Envizio Pro or Viper Pro and Phoenix 300

Provides a wiring diagram for the SmarTrax 3D system with specific field computers.

Raven SmarTrax Specifications

General IconGeneral
BrandRaven
ModelSmarTrax
CategoryFarm Equipment
LanguageEnglish

Related product manuals