P/N 016-0171-277 Rev. L 03/18 E30676
Copyright 2009, 2010, 2011, 2012, 2013, 2017, 2018
SmarTrax™ Calibration and
Operation Manual

Table of Contents

Other manuals for Raven SmarTrax

Questions and Answers

  • S
    sarahdanielsAug 25, 2025
    What does 'No Cal' mean on Raven Farm Equipment and how do I fix it?
    • D
      David SanchezAug 26, 2025
      If your Raven Farm Equipment displays 'No Cal', calibrate the SmarTrax system using the calibration wizard.
  • S
    Sharon SantanaAug 25, 2025
    Why does Raven SmarTrax machine consistently drive to the left or right of the guidance line?
    • E
      Ernest MooreAug 25, 2025
      If your Raven Farm Equipment machine consistently drives to the left or right of the guidance line, recalibrate the yaw sensor to zero while the machine is stationary and reset the SPS/WAS center calibration. Lower the appropriate PWM Min value until the front wheels steer very slowly manually and with minimum buttons. Increase the LA Aggressiveness and OL Sensitivity settings.
  • E
    Erin GreenSep 4, 2025
    What does 'Road Mode' mean on Raven SmarTrax Farm Equipment and how do I fix it?
    • J
      Jennifer RodriguezSep 4, 2025
      If your Raven Farm Equipment is displaying 'Road Mode', switch the roading switch to the on position.
  • G
    Glenn ShawSep 7, 2025
    Why can't I manually steer left or right from the System Diagnostics screen on Raven Farm Equipment?
    • J
      James OlsonSep 7, 2025
      If you cannot manually steer left or right from the System Diagnostics screen on your Raven Farm Equipment, check the hose connections and the node status lights for high current (HC) power. Also, check the power/ground fuses and connections and the solenoids on the SmarTrax valve for proper connection and voltage. Inspect the cable for shorts or breaks. Verify PWM Max settings are set correctly in the field computer and if you have SmarTrax hydraulic valve part numbers 334-0003-056 through 334-0003-079, verify FC adjustment is turned all the way out (typically eight or nine threads are visible beyond the jam nuts).
  • T
    Trevor CraigSep 7, 2025
    Why does Raven SmarTrax Farm Equipment valve makes noise all of the time?
    • M
      maryjensenSep 7, 2025
      If your Raven Farm Equipment valve makes noise all of the time, inspect the load sense orifice for blockage. If the problem persists, install the SmarTrax hydraulic valve recommended for the machine being used.
  • J
    Jason PachecoSep 7, 2025
    Why does Raven Farm Equipment valve makes noise in stand-by mode?
    • J
      javilaSep 7, 2025
      If your Raven Farm Equipment valve makes noise in stand-by mode, adjust the relief valve on the SmarTrax valve until the noise stops.
  • A
    Andrew HallSep 6, 2025
    Why don't the wheels turn fast enough in LA mode on Raven SmarTrax?
    • R
      Rebecca AnthonySep 6, 2025
      If your Raven Farm Equipment wheels do not turn fast enough in LA mode, increase the LA Aggressiveness setting.
  • M
    Maria MartinSep 6, 2025
    What does '3D Hot' mean on Raven SmarTrax Farm Equipment and how do I fix it?
    • D
      Darren GonzalezSep 6, 2025
      If your Raven Farm Equipment displays '3D Hot', recalibrate terrain compensation.
  • J
    John CurtisSep 6, 2025
    What does '3D Cold' mean on Raven Farm Equipment and how do I fix it?
    • T
      Thomas HenrySep 6, 2025
      If your Raven Farm Equipment displays '3D Cold', recalibrate terrain compensation.
  • R
    Robert MooreSep 5, 2025
    What does 'TC Error' mean on Raven Farm Equipment and how do I fix it?
    • E
      Elizabeth SweeneySep 5, 2025
      If your Raven Farm Equipment displays 'TC Error', the SmarTrax node must be repaired or replaced. Contact your local Raven dealer.

Summary

Important Safety Information

Hydraulic Safety

Guidelines for working safely with the hydraulic system, including protective equipment and fluid handling.

Electrical Safety

Precautions for electrical connections, polarity, and voltage requirements for the SmarTrax system.

Introduction

Recommendations

Best practices for installing and operating the SmarTrax system for the first time.

Antenna Installation

Details on positioning the GPS antenna for optimal system performance and accuracy.

CR7 Calibration and Operation

Buttons and Definitions

Explains common status and mode information displayed on the CR7 during SmarTrax operation.

Machine Configuration

Steps for setting up machine profiles and configuring machine-specific settings in the CR7.

Calibrate SmarTrax System

Overview of the SmarTrax calibration wizard and initial setup steps for the system.

System Adjustments

Information on tuning system performance and adjusting parameters like Line Acquisition and Sensitivity.

Viper 4;4+ Calibration and Operation

Widget and Button Definitions

Defines common status icons and buttons used on the Viper 4/4+ display for SmarTrax.

GPS Configuration

Steps to configure GPS settings and ensure proper communication for the SmarTrax system.

Machine Configuration

Process for selecting machine types and setting up profiles for SmarTrax operation on Viper 4/4+.

Calibrate SmarTrax System

Detailed procedure for calibrating the SmarTrax system using the setup wizard.

System Adjustments

Guidelines for fine-tuning SmarTrax performance, including LA and OL modes.

Viper Pro Calibration and Operation

Software Compatibility

Requirements for Viper Pro software and SmarTrax node software versions for compatibility.

SmarTrax Status Display

How to interpret system status messages displayed on the Viper Pro screen.

Machine Configuration

Setting up machine profiles and specific configurations for SmarTrax on Viper Pro.

Calibrate SmarTrax System

Step-by-step guide to calibrating the SmarTrax system with the Viper Pro.

System Adjustments

Tuning SmarTrax parameters like LA and OL sensitivity for optimal field operation.

Envizio Pro and Cruizer II Calibration and Operation

Software Compatibility

Specifies required software versions for Envizio Pro/Cruizer II and SmarTrax node.

SmarTrax Status Display

Interpreting SmarTrax system status icons on the Envizio Pro/Cruizer II display.

Machine Configuration

Steps to configure machine profiles and specific settings for SmarTrax with Envizio Pro/Cruizer II.

Calibrate SmarTrax System

Guide for calibrating the SmarTrax system when used with Envizio Pro or Cruizer II.

System Adjustments

Adjusting SmarTrax settings like LA and OL sensitivity for optimal field operation.

Troubleshooting

Node

Explains SmarTrax CAN control node LEDs for diagnosing system issues.

Error Messages

Lists common SmarTrax error messages, their causes, and corrective actions.

System Diagrams

SmarTrax 3 D with Envizio Pro or Viper Pro and Phoenix 300

Provides a wiring diagram for the SmarTrax 3D system with specific field computers.

Raven SmarTrax Specifications