EasyManua.ls Logo

Raven SmarTrax - User Manual

Default Icon
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
P/N 016-0171-277 Rev. L 03/18 E30676
Copyright 2009, 2010, 2011, 2012, 2013, 2017, 2018
SmarTrax™ Calibration and
Operation Manual

Table of Contents

Other manuals for Raven SmarTrax

Questions and Answers

  • O
    omartinAug 27, 2025
    What to do if I have a 'Guide Com' error on Raven Farm Equipment?
    • B
      bankskyleAug 27, 2025
      If you're experiencing a 'Guide Com' error on your Raven Farm Equipment, it means guidance points are no longer being received by SmarTrax. Verify connections between SmarTrax and the field computer. If you are using Viper Pro, verify that the “Send Guidance Message” option is on the Lightbar Setup screen.
  • C
    Christine BowmanSep 12, 2025
    How to resolve 'No A-B Msg' error on Raven Farm Equipment?
    • D
      Donna RichardsSep 12, 2025
      If you're getting a 'No A-B Msg' error on your Raven Farm Equipment, it indicates that the A-B line has not been set on the field computer or there is no communication from the field computer. To fix this, set the A-B line in the field computer. Also, verify the cabling is correct and secure, and ensure the “Send Guidance” message is selected.
  • J
    Jason ShawAug 27, 2025
    Why is the hydraulic disengage switch or transducer not detected during calibration of my Raven Farm Equipment?
    • K
      Katie HodgesAug 27, 2025
      If the hydraulic disengage switch or transducer is not detected during calibration, the priority valve in the open center valve may be stuck. Consider replacing the cartridge or the open center valve. The cable connection(s) to the disengage switch may also be improperly connected or loose, so verify disengage switch connections are correct and secure. Additionally, the cable connection to the transducer may be improperly connected or loose, so verify the connection to the transducer is correct and secure.
  • G
    Gloria GreenAug 28, 2025
    What does 'Cal' mean on Raven Farm Equipment?
    • V
      Veronica DunnAug 28, 2025
      If you're seeing a 'Cal' message on your Raven Farm Equipment, the /WAS has been detected but not calibrated. Calibrate the /WAS.
  • M
    Michael GutierrezSep 22, 2025
    What does 'Road Mode' mean on Raven Farm Equipment?
    • H
      hartkendraSep 22, 2025
      If you see a 'Road Mode' message on your Raven Farm Equipment, the roading switch is in the off position. Switch the roading switch to the on position.
  • M
    michaelkaneSep 13, 2025
    What causes 'Hyd Stuck' or 'HYDRAULICS_STUCK' error on Raven Farm Equipment?
    • E
      Elizabeth CruzSep 14, 2025
      If you're seeing a 'Hyd Stuck' or 'HYDRAULICS_STUCK' error on your Raven Farm Equipment, it means insufficient or no wheel movement is detected by the field computer. Check all valve hydraulic connections and all valve electrical connections. Also, check the /WAS sensor and connections.
  • L
    lindseyelizabethSep 23, 2025
    What does '3D Hot' mean on Raven Farm Equipment?
    • M
      Margaret RobertsSep 23, 2025
      If you see a '3D Hot' message on your Raven Farm Equipment, it means the system is significantly warmer than when terrain compensation was calibrated. Recalibrate terrain compensation.
  • T
    Tracy MontesSep 23, 2025
    What does '3D Cold' mean on Raven Farm Equipment?
    • D
      Daniel WagnerSep 23, 2025
      If you see a '3D Cold' message on your Raven Farm Equipment, it means the system is significantly cooler than when terrain compensation was calibrated. Recalibrate terrain compensation.
  • L
    Lisa ClarkAug 29, 2025
    What to do if Raven SmarTrax wheels turn the wrong way when the steering wheel is turned?
    • R
      Ryan JamesAug 29, 2025
      If the Raven Farm Equipment wheels turn the wrong way when the steering wheel is turned, reverse the left and right steering hoses on the machine’s steering orbital.
  • B
    Brandon EspinozaAug 29, 2025
    What causes Raven SmarTrax Farm Equipment to display 'Hyd Stuck' or 'HYDRAULICS_STUCK' and how to fix it?
    • S
      Stacy EdwardsAug 30, 2025
      To resolve the Raven Farm Equipment 'Hyd Stuck' or 'HYDRAULICS_STUCK' error, check all valve hydraulic and electrical connections. Also, check the SPS/WAS sensor and connections. If the problem persists, replace the node.

Summary

Important Safety Information

Hydraulic Safety

Guidelines for working safely with the hydraulic system, including protective equipment and fluid handling.

Electrical Safety

Precautions for electrical connections, polarity, and voltage requirements for the SmarTrax system.

Introduction

Recommendations

Best practices for installing and operating the SmarTrax system for the first time.

Antenna Installation

Details on positioning the GPS antenna for optimal system performance and accuracy.

CR7 Calibration and Operation

Buttons and Definitions

Explains common status and mode information displayed on the CR7 during SmarTrax operation.

Machine Configuration

Steps for setting up machine profiles and configuring machine-specific settings in the CR7.

Calibrate SmarTrax System

Overview of the SmarTrax calibration wizard and initial setup steps for the system.

System Adjustments

Information on tuning system performance and adjusting parameters like Line Acquisition and Sensitivity.

Viper 4;4+ Calibration and Operation

Widget and Button Definitions

Defines common status icons and buttons used on the Viper 4/4+ display for SmarTrax.

GPS Configuration

Steps to configure GPS settings and ensure proper communication for the SmarTrax system.

Machine Configuration

Process for selecting machine types and setting up profiles for SmarTrax operation on Viper 4/4+.

Calibrate SmarTrax System

Detailed procedure for calibrating the SmarTrax system using the setup wizard.

System Adjustments

Guidelines for fine-tuning SmarTrax performance, including LA and OL modes.

Viper Pro Calibration and Operation

Software Compatibility

Requirements for Viper Pro software and SmarTrax node software versions for compatibility.

SmarTrax Status Display

How to interpret system status messages displayed on the Viper Pro screen.

Machine Configuration

Setting up machine profiles and specific configurations for SmarTrax on Viper Pro.

Calibrate SmarTrax System

Step-by-step guide to calibrating the SmarTrax system with the Viper Pro.

System Adjustments

Tuning SmarTrax parameters like LA and OL sensitivity for optimal field operation.

Envizio Pro and Cruizer II Calibration and Operation

Software Compatibility

Specifies required software versions for Envizio Pro/Cruizer II and SmarTrax node.

SmarTrax Status Display

Interpreting SmarTrax system status icons on the Envizio Pro/Cruizer II display.

Machine Configuration

Steps to configure machine profiles and specific settings for SmarTrax with Envizio Pro/Cruizer II.

Calibrate SmarTrax System

Guide for calibrating the SmarTrax system when used with Envizio Pro or Cruizer II.

System Adjustments

Adjusting SmarTrax settings like LA and OL sensitivity for optimal field operation.

Troubleshooting

Node

Explains SmarTrax CAN control node LEDs for diagnosing system issues.

Error Messages

Lists common SmarTrax error messages, their causes, and corrective actions.

System Diagrams

SmarTrax 3 D with Envizio Pro or Viper Pro and Phoenix 300

Provides a wiring diagram for the SmarTrax 3D system with specific field computers.

Raven SmarTrax Specifications

General IconGeneral
BrandRaven
ModelSmarTrax
CategoryFarm Equipment
LanguageEnglish

Related product manuals