What does 'Cal' mean on Raven Farm Equipment?
- VVeronica DunnAug 28, 2025
If you're seeing a 'Cal' message on your Raven Farm Equipment, the /WAS has been detected but not calibrated. Calibrate the /WAS.
What does 'Cal' mean on Raven Farm Equipment?
If you're seeing a 'Cal' message on your Raven Farm Equipment, the /WAS has been detected but not calibrated. Calibrate the /WAS.
What to do if Raven Farm Equipment SmarTrax will not power up?
If your Raven Farm Equipment SmarTrax won't power up, check the power connections to ensure they are secure and properly connected. Also, inspect the fuse and replace it if it's blown. Make sure the battery connections are secure, not corroded, and properly connected. Use a voltmeter to test for +12VDC to ensure the machine has proper voltage. Finally, test the cable voltage from the field computer to the node, and if necessary, replace the field computer.
What to do if Raven Farm Equipment SmarTrax will not disengage when the steering wheel is turned?
If your Raven Farm Equipment SmarTrax won't disengage when the steering wheel is turned, adjust the Disengage Setting in the field computer. Also, if you have SmarTrax hydraulic valve part numbers 334-0003-056 through 334-0003-079, turn the knob on the pressure switch out. If the issue persists, replace the faulty pressure disengage switch.
Why is the steering wheel difficult to turn when attempting to disengage Raven Farm Equipment SmarTrax?
If your Raven Farm Equipment steering wheel is difficult to turn when attempting to disengage SmarTrax, turn the knob out on the pressure switch and/or decrease the disengage setting.
What to do if Raven Farm Equipment SmarTrax will not engage by pressing the foot/enable switch?
If your Raven Farm Equipment SmarTrax will not engage by pressing the foot/enable switch, check the LEDs on the node to ensure proper communication. Identify and correct any system errors. Test the voltage (12V) and ground at the disengage switch and pressure transducers to ensure the steer switch override is not active. Adjust the disengage settings and/or pressure switch knob. Test the voltage (12V) and ground on the foot/enable switch cable connection, using a jumper wire to simulate foot/enable switch function.
What to do if Raven SmarTrax wheels turn the wrong way when the steering wheel is turned?
If the Raven Farm Equipment wheels turn the wrong way when the steering wheel is turned, reverse the left and right steering hoses on the machine’s steering orbital.
What causes Raven SmarTrax Farm Equipment to display 'Hyd Stuck' or 'HYDRAULICS_STUCK' and how to fix it?
To resolve the Raven Farm Equipment 'Hyd Stuck' or 'HYDRAULICS_STUCK' error, check all valve hydraulic and electrical connections. Also, check the SPS/WAS sensor and connections. If the problem persists, replace the node.
How to fix jittery wheels while on-line with Raven SmarTrax Farm Equipment?
If you are experiencing jittery wheels while on-line with your Raven Farm Equipment, decrease the OL Sensitivity setting in increments of 1, allowing at least 40 seconds between adjustments. Also, lower PWM Min values until the front wheels steer very slowly manually and with minimum buttons.
Why is Raven SmarTrax Farm Equipment system slowly oscillating while on-line and how to fix it?
To address the Raven Farm Equipment system slowly oscillating while on-line, increase the OL Sensitivity setting in increments of 1, allowing at least 40 seconds between adjustments. Additionally, lower PWM Min values until the front wheels steer very slowly manually and with minimum buttons.
Why is the steering wheel difficult to turn when attempting to turn the vehicle while Raven Farm Equipment SmarTrax is not engaged?
If the Raven Farm Equipment steering wheel is difficult to turn when attempting to turn the vehicle while SmarTrax is not engaged, verify the load sense hoses are installed correctly on the SmarTrax valve.
Brand | Raven |
---|---|
Model | SmarTrax |
Category | Farm Equipment |
Language | English |
Guidelines for working safely with the hydraulic system, including protective equipment and fluid handling.
Precautions for electrical connections, polarity, and voltage requirements for the SmarTrax system.
Best practices for installing and operating the SmarTrax system for the first time.
Details on positioning the GPS antenna for optimal system performance and accuracy.
Explains common status and mode information displayed on the CR7 during SmarTrax operation.
Steps for setting up machine profiles and configuring machine-specific settings in the CR7.
Overview of the SmarTrax calibration wizard and initial setup steps for the system.
Information on tuning system performance and adjusting parameters like Line Acquisition and Sensitivity.
Defines common status icons and buttons used on the Viper 4/4+ display for SmarTrax.
Steps to configure GPS settings and ensure proper communication for the SmarTrax system.
Process for selecting machine types and setting up profiles for SmarTrax operation on Viper 4/4+.
Detailed procedure for calibrating the SmarTrax system using the setup wizard.
Guidelines for fine-tuning SmarTrax performance, including LA and OL modes.
Requirements for Viper Pro software and SmarTrax node software versions for compatibility.
How to interpret system status messages displayed on the Viper Pro screen.
Setting up machine profiles and specific configurations for SmarTrax on Viper Pro.
Step-by-step guide to calibrating the SmarTrax system with the Viper Pro.
Tuning SmarTrax parameters like LA and OL sensitivity for optimal field operation.
Specifies required software versions for Envizio Pro/Cruizer II and SmarTrax node.
Interpreting SmarTrax system status icons on the Envizio Pro/Cruizer II display.
Steps to configure machine profiles and specific settings for SmarTrax with Envizio Pro/Cruizer II.
Guide for calibrating the SmarTrax system when used with Envizio Pro or Cruizer II.
Adjusting SmarTrax settings like LA and OL sensitivity for optimal field operation.
Explains SmarTrax CAN control node LEDs for diagnosing system issues.
Lists common SmarTrax error messages, their causes, and corrective actions.
Provides a wiring diagram for the SmarTrax 3D system with specific field computers.