What does 'Road Mode' mean on Raven Farm Equipment?
- HhartkendraSep 22, 2025
If you see a 'Road Mode' message on your Raven Farm Equipment, the roading switch is in the off position. Switch the roading switch to the on position.





What does 'Road Mode' mean on Raven Farm Equipment?
If you see a 'Road Mode' message on your Raven Farm Equipment, the roading switch is in the off position. Switch the roading switch to the on position.
What causes 'Hyd Stuck' or 'HYDRAULICS_STUCK' error on Raven Farm Equipment?
If you're seeing a 'Hyd Stuck' or 'HYDRAULICS_STUCK' error on your Raven Farm Equipment, it means insufficient or no wheel movement is detected by the field computer. Check all valve hydraulic connections and all valve electrical connections. Also, check the /WAS sensor and connections.
What causes Raven Farm Equipment SmarTrax to not disengage when the steering wheel is turned?
If your Raven Farm Equipment SmarTrax system isn't disengaging when you turn the steering wheel, the Disengage Setting may be incorrect. Adjust the Disengage Setting in the field computer. Also, if you have SmarTrax hydraulic valve part numbers 334-0003-056 through 334-0003-079, the knob on the pressure switch might be turned in too far, so turn the knob on the pressure switch out. The pressure disengage switch may also have failed, requiring you to replace the faulty pressure disengage switch.
What to do if Raven SmarTrax wheels turn the wrong way when the steering wheel is turned?
If the Raven Farm Equipment wheels turn the wrong way when the steering wheel is turned, reverse the left and right steering hoses on the machine’s steering orbital.
What causes Raven SmarTrax Farm Equipment to display 'Hyd Stuck' or 'HYDRAULICS_STUCK' and how to fix it?
To resolve the Raven Farm Equipment 'Hyd Stuck' or 'HYDRAULICS_STUCK' error, check all valve hydraulic and electrical connections. Also, check the SPS/WAS sensor and connections. If the problem persists, replace the node.
How to fix jittery wheels while on-line with Raven SmarTrax Farm Equipment?
If you are experiencing jittery wheels while on-line with your Raven Farm Equipment, decrease the OL Sensitivity setting in increments of 1, allowing at least 40 seconds between adjustments. Also, lower PWM Min values until the front wheels steer very slowly manually and with minimum buttons.
Why is Raven SmarTrax Farm Equipment system slowly oscillating while on-line and how to fix it?
To address the Raven Farm Equipment system slowly oscillating while on-line, increase the OL Sensitivity setting in increments of 1, allowing at least 40 seconds between adjustments. Additionally, lower PWM Min values until the front wheels steer very slowly manually and with minimum buttons.
What does 'VALID POINTS LOW' mean on Raven Farm Equipment?
If you're seeing a 'VALID POINTS LOW' error on your Raven Farm Equipment, not enough valid measurements are being received by the steering control device during calibration. Verify that the SmarTrax hydraulic hose, fitting, and valve connections are secure and no leaks are present. Verify that harness cable connections are correct and securely installed. Check the steering linkages to ensure they are connected securely and meet the machine manufacturer’s factory specifications.
Why does Raven Farm Equipment SmarTrax disengage only when the steering wheel is turned one way?
If your Raven Farm Equipment SmarTrax system disengages only when the steering wheel is turned one way, the flow disengage switch has failed on one side. Replace the faulty flow disengage switch.
What does 'Too FAST' mean on Raven Farm Equipment and how to resolve it?
The 'Too FAST' error on Raven Farm Equipment indicates that the vehicle speed is above 29 mph [45 km/h] or has been above 27 mph for more than 5 seconds, and SmarTrax has been disengaged. To resolve this, decrease the vehicle speed and re-engage the SmarTrax system.
| Brand | Raven |
|---|---|
| Model | SmarTrax |
| Category | Farm Equipment |
| Language | English |
Guidelines for working safely with the hydraulic system, including protective equipment and fluid handling.
Precautions for electrical connections, polarity, and voltage requirements for the SmarTrax system.
Best practices for installing and operating the SmarTrax system for the first time.
Details on positioning the GPS antenna for optimal system performance and accuracy.
Explains common status and mode information displayed on the CR7 during SmarTrax operation.
Steps for setting up machine profiles and configuring machine-specific settings in the CR7.
Overview of the SmarTrax calibration wizard and initial setup steps for the system.
Information on tuning system performance and adjusting parameters like Line Acquisition and Sensitivity.
Defines common status icons and buttons used on the Viper 4/4+ display for SmarTrax.
Steps to configure GPS settings and ensure proper communication for the SmarTrax system.
Process for selecting machine types and setting up profiles for SmarTrax operation on Viper 4/4+.
Detailed procedure for calibrating the SmarTrax system using the setup wizard.
Guidelines for fine-tuning SmarTrax performance, including LA and OL modes.
Requirements for Viper Pro software and SmarTrax node software versions for compatibility.
How to interpret system status messages displayed on the Viper Pro screen.
Setting up machine profiles and specific configurations for SmarTrax on Viper Pro.
Step-by-step guide to calibrating the SmarTrax system with the Viper Pro.
Tuning SmarTrax parameters like LA and OL sensitivity for optimal field operation.
Specifies required software versions for Envizio Pro/Cruizer II and SmarTrax node.
Interpreting SmarTrax system status icons on the Envizio Pro/Cruizer II display.
Steps to configure machine profiles and specific settings for SmarTrax with Envizio Pro/Cruizer II.
Guide for calibrating the SmarTrax system when used with Envizio Pro or Cruizer II.
Adjusting SmarTrax settings like LA and OL sensitivity for optimal field operation.
Explains SmarTrax CAN control node LEDs for diagnosing system issues.
Lists common SmarTrax error messages, their causes, and corrective actions.