Figure 12-28. Procedure for Stopping Master Transmission
Starting setting to stop
Stopping communication
Write 1 to the STmn bit of the target
channel.
Stop communication in midway.
Set the SOEmn bit to 0 and stop the
output of the target channel.
Setting the STm register
Changing setting of the SOEm register
TSFmn = 0?
If there is any data being transferred,
wait for their completion.
Y
N