EasyManuals Logo

REXROTH ECODRIVE03 User Manual

REXROTH ECODRIVE03
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #120 background imageLoading...
Page #120 background image
6-4 Index ECODRIVE03-SGP-03VRS
DOK-ECODR3-SGP-03VRS**-WA01-EN-P
Low battery voltage 4-11
M
Mains fault 4-16, 4-36, 4-42
Master drive encoder failure
quadrant error 4-13
signal too small 4-12
Max signal frequency of encoder 2 exceeded 4-11
Max. signal frequency of encoder 1 exceeded 4-7
Maximum braking time exceeded 4-6
Measuring wheel operation not possible 5-26
Modulo range error 5-14
Motion range exceeded during commutation 4-22, 5-23
Motor feedback data not valid 5-27
Motor overload 4-28
Motor overtemp. prewarning 4-31
Motor overtemperature shutdown 4-4
Motor temp. surveillance defective 4-5
Motor type P-0-4014 incorrect 5-9
N
Negative limit switch activated 4-41
Negative position limit exceeded 4-40
Negative travel limit exceeded 4-19
Negative travel limit switch detected 4-21
No adjustment with asynchronous motor 5-22
No ready signal from supply module 4-16, 4-37, 4-42
Not homed 4-32
O
Only allowed without master 5-17
Operation status 5-43
Order of MDT configuration wrong 5-7
Overcurrent
short in power stage 4-24
Overflow of target position preset memory 4-12
Overvoltage in power stage 4-38
P
P0 5-44
P1 5-44
P2 5-44
P3 5-44
Parameter calculation error (->S-0-0022) 5-9
Parameter default value erroneous (-> S-0-0021) 5-21
Parameter limit error (->S-0-0022) 5-8
Parameters not copyable 5-20
Parking axis command 5-25
Parking axis only while drive is disabled 5-25
Phase switching without ready signal 4-18
Phase synchr. lagless, encoder 1, real master drive 5-35
Phase synchr. lagless, encoder 1, virtual master drive 5-34
Phase synchr. lagless, encoder 2, virtual master drive 5-35
Phase synchronization, encoder 1, real master drive 5-34
Phase synchronization, encoder 1, virtual master drive 5-34
Phase synchronization, encoder 2, virtual master drive 5-34
PL 5-44
PL Load parameter default values 4-3
Position control lagless, feedback 2 5-32
Position data scaling error 5-10
Position limit reached during jog 4-40
Position mode lagless, encoder 1 5-32
Position mode with encoder 1 5-31
Position mode with encoder 2 5-32
Position of data record in MDT (S-0-0009) even 5-5