SERVICE PROGRAM MODE TABLES 20 June 2005
5-56
Supply Name Setting 5841
Press the User Tools key. These names appear when the user presses the Inquiry
button on the User Tools screen.
5841 1 Toner Name Setting: Black
5841 7 Org Stamp
5841 11 StapleStd1
5841 12 StapleStd2 Standard Staples for B698
5841 13 StapleStd3 Standard Staples for B700/B701
5841 14 Staple Std4
5841 21 StapleBind1
5841 22 StapleBind2 Booklet Staples for B700
5841 23 StapleBind3
Net File Analysis Mode Setting
DFU
Bit Groups
0 System & other groups (LSB)
1 Capture related
2 Certification related
3 Address book related
4 Machine management related
5 Output related (printing, delivery)
5842*
This is a debugging tool. It sets
the debugging output mode of
each Net File process.
Bit SW 0011 1111
6 Repository related
5844* USB
Transfer Rate Full Speed / Auto Change 5844 1*
Sets the speed for USB data transmission.
Full Speed: (12 Mbps fixed)
Auto Change: 480 Mbps/12 Mbps auto adjust
Vendor ID [0x0000~0xFFFF/ 0x05CA /1], DFU 5844 2*
Sets the vendor ID: Initial Setting: 0x05CA Ricoh Company.
Product ID [0x0000~0xFFFF/ 0x0403 /1], DFU 5844 3*
Sets the product ID.
Device Release Number [0000~9999/ 0100 /1], DFU 5844 4*
Sets the device release number of the BCD (binary coded decimal) display.
Enter as a decimal number. NCS converts the number to hexadecimal number
recognized as the BCD.