SERVICE PROGRAM 9 March 2004
5-34
5404*
User Code Count Clear
5404 1 Initializes the user code counter.
5501*
PM Alarm Interval
Printout [0 ~ 9999 /
0
/ 0K copies/step] 5501 1
Specifies when the PM alarm occurs.
ADF [0 = Off /
1
= On] 5501 2
Enables or disables the original count alarm.
5504
* Jam Alarm [0~3 /
3
/ 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5504 1
Selects the jam alarm level. The jam alarm counter increases if a paper jam occurs
(excluding ADF-related jams). The jam alarm counter decreases if no paper jam
occurs while the copier prints the specified number of paper. The alarm call occurs
if the jam alarm counter reaches 10.
5505* Error Alarm [0 ~ 255 / 20 / 1 hundred sheets/step]
5505 1
Specifies the number of paper (in hundred) used as the error alarm level. The error
alarm starts if 5 SC codes are generated before the copier prints the specified
number of paper. When the copier has printed the specified number of paper, the
SC code counter (of this SP) is cleared to zero.
5507
* Supply Alarm Specifies the supply alarm level.
5507 1 Paper Supply Alarm
0: Off
, 1: On,
DFU
5507 3 Toner Supply Alarm
0: Off
, 1: On,
DFU
5507 128 Interval :Others
5507 133 Interval: A4
5507 134 Interval: A5
5507 142 Interval: B5
5507 164 Interval: LG
5507 166 Interval: LT
5507 172 Interval: HLT
[00250 ~ 10000 /
1000
/ 1 Step]
DFU