9 March 2004 BIT SWITCHES
3-33
Service
Tables
G3-1 Switch 0B SP No. 1-105-012
No FUNCTION COMMENTS
0 Protocol requirements: Europe
0: Disabled 1: Enabled
1 Protocol requirements: Spain
0: Disabled 1: Enabled
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
2 Not used Do not change the setting.
3 Protocol requirements: France
0:
Disabled
1:
Enabled
4 PTT requirements: Germany
0:
Disabled
1:
Enabled
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
5-7
Not used Do not change the settings.
G3-1 Switch 0C SP No. 1-105-013
No FUNCTION COMMENTS
0
to
1
Pulse dialing method
Bit 1 Bit 0 Setting
0 0 Normal (P=N)
0 1 Oslo (P=10 - N)
1 0 Sweden (N + 1)
1 1 Not used
P = Number of pulses sent out, N = Number dialed.
2-7
Not used Do not change the settings.
G3-1 Switch 0D - Not used (Do not change the settings.)
G3-1 Switch 0E SP No. 1-105-015
No FUNCTION COMMENTS
0
to
7
CNG transmission OFF interval.
To input a value more than 3 s, use
bits 3 to 0, and keep bits 4 to 7 at 0.
3000 + 50 x N ms
To inpu a value less than 3 s, use bits
4 to 7, and keep bits 0 to 3 at 1.
3000 – 50 x N ms
Examples:
3100 ms: 50 x 2 = 100
Bits 4 to 7 must be 0
Bits 0 to 3 must be 2(H)
So, enter 02H.
2800 ms: 50 x 4 = 200
Bits 0 to 3 must be F(H)
Bits 4 to 7 must be 4(H)
So, enter 4FH