BIT SWITCHES 9 March 2004
3-34
G3-1 Switch 0F SP No. 1-105-016
No FUNCTION COMMENTS
0
Alarm when an error occurred
in Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each
error communication, change this bit to “1”.
1
Alarm when the handset is off-
hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax communication,
change this bit to “1”.
2-7
Not used Do not change the settings.