and
Adjustment
5. Adjust the side-to-side registration (S to S/Front Regist: SP6-006-001, S to S/Rear Regist:
SP6-006-002). The image area moves to the rear side of the copier when you specify a larger
value.
6. Measure the distance between the leading of the image area and the leading edge of the
paper [B].
7. Adjust the leading edge registration (Leading Regist: SP6-006-003). The image area moves
to the right side of the copier when you specify a larger value.
8. Measure the distance between the trailing edge of the image area and the trailing edge of the
paper [C].
9. Adjust the erased area on the trailing edge (Trailing Erase: SP6-006-007).
10. Compare the copy with the original.