Loading...
G147 5-106 SM
5.6 MEMORY CLEAR: SP5801
Executing Memory Clear resets all the settings stored in the NVRAM to their default settings,
except the following:
SP5811-1: Machine serial number
SP5907: Plug & Play Brand Name and Production Name Setting
This procedure restores all SP code settings to their factory default settings.
Before clearing all settings in memory with SP5801, print an SMC report with
SP5990. You may need this for reference to restore previously adjusted settings.
1. Push " and $ together, hold down for over 5 seconds, release and then press
[#Enter].
2. Press " or $ to display “2.Engine”.
3. Press [#Enter].
4. Press " or $ to display “5.Mode” then press [#Enter].
5. Press " or $ to display “SP5801/Memory Clear” then press [#Enter].
6. With “Clear All” displayed, press [#Enter], then press [#Enter] again to execute.
<All>
result=OK
Here is a summary of all the settings.
No. Item What It Initializes
001 All All items in this table
002 Clear Engine All settings set for engine and processing
003 SCS System Control Service (ROM update information)
004 IMH Image Memory Handler
005 MCS
008 PRT Printer defaults
010 WebService
Netfile (NFA) management files, thumbnails, the Job
login ID.

Table of Contents