G147 5-108 SM
5.7 SMC REPORT
1. To enter the SP mode, push and hold down "$ for 5 sec. then push [#Enter].
<Engine>
1.Feed
2. Press " or $ until you see “5.Mode”.
<Engine>
5.Mode
3. Press [#Enter].
SP5024
mm/inch Display
4. Press $ to select SP5990.
SP5990 >>
SP Print Mode
5. Press [#Enter].
SP5990-001
All (Data List)
6. Press " or $ to select the report that you want to print.
SP Title What It Prints Length
001 All (Data List) Prints all reports 14 pp.
002 SP (Mode Data List)
Prints all SP codes settings for SP Groups 1
to 5 with default and current settings.
3 pp.
004 Logging Data
Prints all SP Code settings for SP7000,
SP800 only.
4 pp.
005 Diagnostic Report
Prints the Self-Diagnosis report (lists all
firmware modules by name and version
number).
1 pp.
006 Non-Default Prints a list of commonly adjusted SP 1 pp.