1. Touch to select Feed Test from the SCANNER TESTS menu.
2. The panel displays the setting's current value [setting's current value] . Use the arrows to select
from Letter, Legal, or A4.
3. Touch "START" to begin.
"Running Flatbed…" displays. Press "4" to exit the test.
4. Touch "Back" to return to the Diagnostics Menu.
Sensor tests
The following tests are available:
P - Sensor (ADF Paper Present)
A - Sensor (ADF cover closed interlock)
F -Sensor (FB scanner cover interlock)
1 - Sensor (ADF sensor 1)
2 - Sensor (ADF sensor 2)
H - Sensor (FB Home position)
1. Touch to select "Sensor Test" from the SCANNER TESTS menu.
2. The display will show P, F, H, A, 1, 2 in a vertical column.
• It is not necessary to test all scanner sensors when Scanner Tests is selected.
3. To test the paper present sensor, push back on the actuator (A). If the sensor is functioning, the 0
next to the P on the display will change to 1.
Diagnostics Menu
181