Error Codes
D255/D256 FAX OPTION 32 SM
Code Meaning Suggested Cause/Action
6-04 G3 ECM - RTC not detected
Check the connection.
Check for a bad line or defective remote
terminal.
Replace the FCU.
6-05
G3 ECM - facsimile data
frame not received within 18 s
of CFR, but there was no line
fail
Check the connection.
Check for a bad line or defective remote
terminal.
Replace the FCU.
Try adjusting the RX cable equalizer
Reference:
RX cable equalizer - G3 Switch 07 (PSTN)
6-06
G3 ECM - coding/decoding
error
Defective FCU.
The other terminal may be defective.
6-08
G3 ECM - PIP/PIN received in
reply to PPS.NULL
The other party pressed [Stop] during
communication.
The other terminal may be defective.
6-09 G3 ECM - ERR received
Check for a noisy line.
Adjust the TX levels of the communicating
machines.
See code 6-05.
6-10
G3 ECM - error frames still
received at the other party
after all communication
attempts at 2400 bps
Check for line noise.
Adjust the TX level (use NCU parameter
01 or the dedicated TX parameter for that
address).
Check the connection.
Defective remote terminal.
6-21
V.21 flag detected during high
speed modem communication
The other terminal may be defective or
incompatible.
6-22
The machine resets the
sequence because of an
abnormal handshake in the
V.34 control channel
Check for line noise.
If the same error occurs frequently, replace
the FCU.
Defective remote terminal.