Loading...
Any of
SP2-194-010 or
011 or 012 shows
“5”
Result of Check Image density low
Causes Pattern density low
Solution
Execute the process control
Supply toner
Pattern -
Result of Check
Leading edge registration for “M”, “C”, and/or
“Y” shifts over ±1.4mm from that of “K”.
Causes
1. Normal
2. Laser unit failure
3. BCU(IPU) failure
Solution
1. Execute SP2-111-003 (Forced Line Position Adj.:
Mode c)
2. Replace Laser unit
3. Replace BCU(IPU)