SC No. Level Error Name/Error Condition/Major Cause/Solution
SC551-02 A Edge NC Sensor Disconnection
3ED - 3FF (FB voltage: 3.243V-3.300V) is detected for (t13) seconds
continuously (NC sensor center: detection & compensation NC sensor
edge: detection & compensation).
Detection period: 100 ms, detection frequency: 10 times or more.
NC sensor disconnection
Connector disconnected
Replace the NC sensor
Reset the connector
Replace the connector
Replace the fusing unit
SC551-03 A
Edge NC Sensor Short-circuit
AD value: 0-13 (FB voltage: 0.000V-0.041V) (*3) is detected for (t14)
seconds continuously.
Detection period: 100 ms, detection frequency: 10 times or more.
NC sensor short-circuit
Connector disconnected
Replace the NC sensor
Reset the connector
Replace the connector
Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC552-02 A Fusing Central Thermopile Does Not Reload
(T21) degrees C not reached after heater 1 ON for (t3) seconds.
SC552-03 A Fusing Central Thermopile Does Not Reload
Heating edge reload permission temperature not reached after heater 1
ON for (t312) seconds.