SC No. Level Error Name/Error Condition/Major Cause/Solution
Thermopile lens dirt
Thermopile modification, float
Outside input voltage guarantee
After excessive temperature rise prevention unit operation
Replace the thermopile.
Make sure that the input voltage is within acceptable limits.
Replace the fusing unit.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC553-00 A Fusing End Thermopile High Temperature Detection (software)
Above (T3) degrees C detected for (t4) seconds continuously.
Detection period: 100ms, detection count: 10 times or more.
Triac short-circuit
IOB defective
BCU defective
Replace the IOB
Replace the BCU
Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC554-01 A Fusing end thermopile high temperature detection (hardware)
In the event of an error
Triac defective (short-circuit)
Engine controller defective
Heating edge thermopile defective
Fusing control software: out of control
If the triac is defective, replace the AC power supply board
If necessary, replace the BCU or heating edge thermopile
5. Troubleshooting