SC No. Level Error Name/Error Condition/Major Cause/Solution
SC574-00 A Pressurized Edge Thermistor High Temperature Detection (hardware)
Above (T4) degrees C detected
Triac short-circuit
IOB defective
BCU defective
Fusing control: out of control
Replace the IOB
Replace the BCU
Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC581-00 A Pressurized Expanded Edge Thermistor Disconnection
Below 0 degree C (or above 3F9) detected for (t12) seconds
continuously.
Detection period: 100ms, detection count: 10 times or more.
Thermistor disconnection
Connector disconnected
Replace the thermistor
Reset the connector
Replace the connector
Replace the fusing unit
Service Call 501-584