SC No. Level Error Name/Error Condition/Major Cause/Solution
SC582-04 A Pressurized Expanded Edge Thermistor Does Not Reload
After starting continuous job with paper width of 257mm or more, does
not reach (T22) degrees C after (t313) seconds.
Thermistor dirt
Thermistor deformation, float
Outside input voltage guarantee
After excess temperature rise prevention unit operation
Replace the thermistor
Make sure that the input voltage is within acceptable limits
Replace the fusing unit
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC583-00 A Pressurized Expanded Edge Thermistor High Temperature Detection
(software)
Above (T3) degrees C detected for (t4) seconds continuously.
Detection period: 100ms, detection count: 10 times or more.
Triac short-circuit
IOB defective
BCU defective
Replace the IOB
Replace the BCU
Replace the fusing unit