SC No. Level Error Name/Error Condition/Major Cause/Solution
SC723-03 B Power Supply Error (Internal Finisher: Non-Staple Bind)
When original source 24V power supply is ON, protection device
intercept of non-interlock power supply system is detected.
A motor failure or harness short-circuit occur in the non-interlock power
supply system.
Replace the short-circuited harnesses
Replace the protection devices
SC723-10 B Transport Motor Error (Internal Finisher: Non-Staple Bind)
The DCM driver error detection is started after reset, and T9[msec] error
signal is detected.
This SC will be issued when the above phenomenon repeated 2 times.
Transport Motor failure
Harness short-circuit
Circuit board failure
Over current
Abnormal temperature
Replace the motor
Replace the harness
Replace the circuit board.