SC No. Level Error Name/Error Condition/Major Cause/Solution
SC723-44 B
Stapler Motor Error (Internal Finisher: Non-Staple Bind)
When the stapler HP sensor was not turned off while T7[msec] applied to
the stapler motor with the HP sensor turned on.
When stapler HP sensor was not turned on while T6[msec] applied to the
stapler motor with the HP sensor turned off.
The STM driver error detection is started after reset, and T9[msec] error
signal is detected.
This SC will be issued when the above phenomenon repeated 2 times.
Stapler Motor failure
Connector disconnected
Stapler Motor overload
Stapler HP sensor error
Harness short-circuit
Circuit board failure
Excess current
Abnormal temperature
Check the connection
Replace the motor/sensor
Replace the harness
Replace the circuit board
Service Call 700-792