SC No. Level Error Name/Error Condition/Major Cause/Solution
SC724-32 B
Jogger Rear Motor Error (Internal finisher)
• When rear jogger motor is driven for T24 msec when rear jogger HP
sensor is ON, the HP sensor does not switch OFF (1st time is jam
notification, 2nd time is SC notification).
• When rear jogger motor is driven for T25 msec when rear jogger HP
sensor is OFF, the HP sensor does not switch ON (1st time is jam
notification, 2nd time is SC notification).
SC724-33 B
Strike Roller Motor Error (Internal finisher)
• During initialization/strike descent, even when the strike roller motor
is driven for T1 msec when the strike roller HP sensor is ON, the HP
sensor does not switch OFF (1st time is jam notification, 2nd time is
SC notification).
• During initialization, even when the strike roller motor is driven for T2
msec when the strike roller HP sensor is OFF, the HP sensor does not
switch ON (1st time is jam notification, 2nd time is SC notification).
• When the strike roller is lifted from the press position, even when
driven for T2 msec, the HP sensor does not switch ON (1st time is
jam notification, 2nd time is SC notification).
SC724-38 B
Paper Press Motor Error (Internal finisher)
• When the paper press HP sensor is ON and the paper press motor is
driven for T14 msec, the HP sensor does not switch OFF (1st time is
jam notification, 2nd time is SC notification).
• When the paper press HP sensor is OFF and the paper press motor
is driven for T15 msec, the HP sensor does not switch ON (1st time is
jam notification, 2nd time is SC notification).
SC724-42 B
Stapler Displacement Movable Motor Error (Internal finisher)
• Sifter stapler displacement HP sensor ON, even when the stapler
displacement motor is driven for T9 msec, the HP sensor does not
switch OFF (1st time is jam notification, 2nd time is SC notification).
• After stapler displacement HP sensor OFF, even when the stapler
displacement motor is driven for T10 msec, the HP sensor does not
switch ON (1st time is jam notification, 2nd time is SC notification).
5. Troubleshooting
546