SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-02 D
Log Data Error 2
An error was detected in the handling of the log data at power on or
during machine operation.
Log encryption is enabled but encryption module is not installed.
Replace or set again the encryption module.
Disable the log encryption setting.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-03 D
Log Data Error 3
An error was detected in the handling of the log data at power on or
during machine operation.
Inconsistency of encryption key between NV-RAM and HDD.
Disable the log encryption setting.
Initialize LCS memory (SP5801-019).
Initialize the HDD (SP5-832-004).
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-04 D
Log Data Error 4
An error was detected in the handling of the log data at power on or
during machine operation.
Log encryption key is disabled but the log data file is encrypted.
(NVRAM data corruption)
Log encryption key is enabled but the log data file is not encrypted.
(NVRAM data corruption)
Initialize the HDD (SP5-832-004).