SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-05 D
Log Data Error 5
An error was detected in the handling of the log data at power on or
during machine operation.
Only the NV-RAM has been replaced with one previously used in
another machine.
Only the HDD has been replaced with one previously used in
another machine.
Attach the original NV-RAM.
Attach the original HDD.
With the configuration that caused the SC, initialize the HDD
(SP5-832-004).
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC876-99 D
Log Data Error 99
An error was detected in the handling of the log data at power on or
during machine operation.
Other causes
-
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC877-00 B
Data Overwrite Security card error
The "Auto Erase Memory" function of the Data Overwrite Security is set to
on but it cannot be done.
Data Overwrite Security option SD card is broken.
Data Overwrite Security option SD card has been removed.
If the SD card is broken, prepare a new Data Overwrite Security
option SD card and replace the NVRAM.
If the SD card has been removed, turn the main power off and
reinstall a working Data Overwrite Security option SD card.
5. Troubleshooting
608