E62 “GRIPPER NOT IN POSITION” ALARM
Cause:
- Clamp cylinder magnetic sensors not properly working.
Remedy:
- Check and replace the sensor if necessary.
E63 "CLAMP CLOSED" ALARM
Cause:
- Clamp cylinder magnetic sensors not properly working.
Remedy:
- Check and replace the sensor if necessary.
E64 "FILM RUPTURE" ALARM
Cause:
- The film has broken or reel is empty.
Remedy:
- Insert the film or replace reel.
E65 WARNING “UPPER GRIPPER NOT IN POSITION”
Cause:
- Magnetic sensors of the upper gripper cylinders are malfunctioning.
Remedy:
- Check and replace the sensor if necessary.
E66 WARNING “UPPER CUT-OFF NOT IN POSITION”
Cause:
- Magnetic sensors of the upper cut-off cylinder are malfunctioning.
Remedy:
- Check and replace the sensor if necessary.
E67 “BLADE NOT IN POSITION” ALARM
Cause:
- Clamp cylinder magnetic sensors not properly working.
Remedy:
- Check and replace the sensor if necessary.
E68 “STOPPER NOT IN POSITION” ALARM
Cause:
- Clamp cylinder magnetic sensors not properly working.
Remedy:
- Check and replace the sensor if necessary.
E69 “WELDER NOT IN POSITION” ALARM
Cause:
- Clamp cylinder magnetic sensors not properly working.
Remedy:
- Check and replace the sensor if necessary.