EasyManuals Logo
Home>Rockwell Automation>Controller>Allen-Bradley Dialog Plus 1503D

Rockwell Automation Allen-Bradley Dialog Plus 1503D User Manual

Rockwell Automation Allen-Bradley Dialog Plus 1503D
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
1-2 Product Overview
1560D-UM051D-EN-P – February 2005
Description (cont.) 1562D – Combination Controller
A medium voltage solid-state controller that provides isolation and
protection for new installations. It includes:
Tin-plated, copper, horizontal power bus (optional)
A continuous, bare copper ground bus
Power electronics
A main non-load-break isolating switch and operating handle
An isolation vacuum contactor
A bypass vacuum contactor
Three (3) current limiting power fuses for NEMA Class E2 operation
Three (3) current transformers
A control power transformer (optional)
A low voltage control panel complete with microprocessor-based control
module
Space for necessary auxiliary control and metering devices
Top and bottom plates to accommodate power cables
Motor overload protection
Dialog Plus™ Control Module
The MV Dialog Plus controller offers a full range of starting modes as standard:
Soft Start with Selectable Kickstart
Current Limit Start with Selectable Kickstart
Dual Ramp Start
Full Voltage Start
Other features that offer further user benefit include:
Expanded protective features
Metering
Communication capability
Innovative starting and stopping options provide enhanced performance:
Soft Stop
Pump Control
X
Preset Slow Speed Y
SMB™ Smart Motor Braking Y
Slow Speed with Braking Y
These modes, features and options are further described in this chapter.
NOTE: The Accu-Stop™ option is not available in the MV Dialog Plus.
X The MV Dialog Plus product uses a modified version of the Bulletin 150 Pump Control Module. Do not use
a pump module for the low voltage product line in the medium voltage product. There is no difference for
the standard or soft stop modules.
Y These options utilize gating patterns which result in motor and line currents that produce noise and vibration
in the motor and/or distribution transformer. The factory should be consulted before applying these options.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Dialog Plus 1503D and is the answer not in the manual?

Rockwell Automation Allen-Bradley Dialog Plus 1503D Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Dialog Plus 1503D
CategoryController
LanguageEnglish

Related product manuals