Options 7-7
1560D-UM051D-EN-P – February 2005
SMB Smart Motor Braking
Option
Motor Speed
Push Buttons
Start
Stop
Soft Stop
Auxiliary
Contacts
Normal
Up-to-speed
Start Run
Open
Open
Open
Closed
Closed
Closed
100%
Coast-to-rest
Automatic Zero Speed
Shut-off
Smart Motor Braking
Brake
Time (seconds)
Coast-to-rest Operation
Smart Motor Braking Operation
Motor Speed
Push Buttons
Start
Stop
Soft Stop
Auxiliary
Contacts
Normal
Up-to-speed
Start Run
Open
Open
Open
Closed
Closed
Closed
100%
Coast-to-rest
Automatic Zero Speed
Shut-off
Smart Motor Braking
Brake
Time (seconds)
Coast-to-rest Operation
Smart Motor Braking Operation
Figure 7.3 – SMB Smart Motor Braking Sequence of Operation
The user is responsible for determining which stopping
mode is best suited to the application and will meet
applicable standards for operator safety on a particular
machine. Failure to do so may result in severe injury
and/or equipment damage.
A T T E N T I O NA T T E N T I O N