Specifications and Dimensions 179
Contactor Ratings
The table below lists the recommended contactor ratings for
integrated axis modules installed without a line interface module.
Transformer Specifications for Control Power Input
Catalog Number
230V IAM
Contactor
Catalog Number
460V IAM
Contactor
2094-AC05-MP5-S
100-C23x10 (ac coil)
100-C23Zx10 (dc coil)
2094-BC01-MP5-S
100-C23x10 (ac coil)
100-C23Zx10 (dc coil)
2094-AC05-M01-S 2094-BC01-M01-S
2094-AC09-M02-S
100-C37x10 (ac coil)
100-C37Zx10 (dc coil)
2094-BC02-M02-S
100-C37x10 (ac coil)
100-C37Zx10 (dc coil)
2094-AC16-M03-S
100-C72x10 (ac coil)
100-C72Zx10 (dc coil)
2094-BC04-M03-S
100-C60x10 (ac coil)
100-C60Zx10 (dc coil)
2094-AC32-M05-S
100-C85x10 (ac coil)
100-C85Zx10 (dc coil)
2094-BC07-M05-S
100-C72x10 (ac coil)
100-C72Zx10 (dc coil)
Attribute Value (460V system)
Input volt-amperes 750VA
Input voltage 460V ac
Output voltage 120...240V ac

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley Kinetix 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Kinetix 6000 and is the answer not in the manual?

Rockwell Automation Allen-Bradley Kinetix 6000 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Kinetix 6000
CategoryServo Drives
LanguageEnglish

Related product manuals