EasyManua.ls Logo

Rockwell Automation Allen-Bradley Kinetix 6000 - Contactor Ratings; Transformer Specifications for Control Power Input

Rockwell Automation Allen-Bradley Kinetix 6000
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Publication 2094-UM001A-EN-P — September 2006
Specifications and Dimensions 179
Contactor Ratings
The table below lists the recommended contactor ratings for
integrated axis modules installed without a line interface module.
Transformer Specifications for Control Power Input
Catalog Number
230V IAM
Contactor
Catalog Number
460V IAM
Contactor
2094-AC05-MP5-S
100-C23x10 (ac coil)
100-C23Zx10 (dc coil)
2094-BC01-MP5-S
100-C23x10 (ac coil)
100-C23Zx10 (dc coil)
2094-AC05-M01-S 2094-BC01-M01-S
2094-AC09-M02-S
100-C37x10 (ac coil)
100-C37Zx10 (dc coil)
2094-BC02-M02-S
100-C37x10 (ac coil)
100-C37Zx10 (dc coil)
2094-AC16-M03-S
100-C72x10 (ac coil)
100-C72Zx10 (dc coil)
2094-BC04-M03-S
100-C60x10 (ac coil)
100-C60Zx10 (dc coil)
2094-AC32-M05-S
100-C85x10 (ac coil)
100-C85Zx10 (dc coil)
2094-BC07-M05-S
100-C72x10 (ac coil)
100-C72Zx10 (dc coil)
Attribute Value (460V system)
Input volt-amperes 750VA
Input voltage 460V ac
Output voltage 120...240V ac

Table of Contents