230 Upgrading Firmware
The flash upgrade operation begins and the following dialog
opens.
The flash operation completes and the following dialog opens.
9. Close the HyperTerminal session.
10. Verify that parameter 30 for each axis module is now upgraded to
the new firmware revision.
11. Return to DriveExplorer (refer to Selecting Axis Modules to
Upgrade, Step 5) to see the linear list of parameters.
ATTENTION
To avoid unrecoverable fault to drive modules, do not
interrupt control power to IAM, power to the 1203-SSS
SCANport adapter, or power to your PC while the flash
upgrade operation is in progress.