Maintenance
Repair
124 MagneMotion
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
If the node controller being replaced had eight or fewer connections, only one NC-S is
required for replacement. If the connections used only Ports 1–8, no changes are required. If
any connections used Ports 9–12, those connections must be reconfigured to one of the avail-
able ports on the NC-S.
When redistributing the connections, make sure that all connections for a node are made to the
same node controller.
1. Run the MagneMotion Configurator and open a copy of the current Node Controller
Configuration File.
2. In the Node Controllers section of the Configuration Tree, open the Node Control-
ler Details page for the node controller being replaced.
Remove ownership of those nodes that are connected to Comm Ports 9–12.
3. In the Node Controllers section of the Configuration Tree, add a new node control-
ler.
A. Set the IP address of the new node controller to match the IP address of the
second NC-S added.
B. Take ownership of those nodes that were connected to Comm Ports 9–12.
C. Select the appropriate Comm Port for each connection.
4. Save the revised Node Controller Configuration File with a new name to identify it.