Specifications and Site Requirements
Electrical Specifications
82 MagneMotion
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Ethernet Switch with Power over Ethernet Injector
The Power over Ethernet switch provides +18V DC @ 2 A max/port for the NC LITE.
18V DC, 100 W max based on configuration and operating mode.
AC Power Option
The optional remote power supply for the Ethernet switch requires 85–264V AC @ 47–63 Hz,
single-phase (phase-to-phase or phase-to-neutral), <1.0 A rms (100 W max), based on config-
uration and operating mode. Inrush current <37 A at 230V AC cold start. The actual power
being drawn depends upon operations being performed, however all power wiring and all
Ethernet cables that are used for PoE must be sized to carry the full load. See the data sheet
provided by the power supply manufacturer for mechanical information.
AC Power Cable
The Ethernet Switch with PoE power supply is supplied with a power cable. Contact Magne-
Motion for replacement cables. The AC power cable plugs directly into the power supply.
DC Power Option
DC power from a user-supplied power supply requires 18V DC, 100 W.
The actual power being drawn depends on the operations being performed. Make sure that all
power wiring can carry the full load and has a limited power source or the power source is
fused to the maximum rating of the wiring.
NOTICE
The voltage that is provided by the Power over Ethernet switch is non-stan-
dard (18V DC) and the switch does not disable power at any port.
Connecting any device other than an NC LITE to the PoE switch can dam-
age the device.
CAUTION
High-Voltage Hazard
85–264V AC, 100 W
AC power must be disconnected before servicing.
NOTICE
Any user-supplied power supply must be NRTL/ATL approved.