R&S PR100 User Manual
d
OUTPut
. :IF
. . [:STATe] <Boolean>
Sets the IF output state. If it is ON, the MR activates a separate output on
which it puts the received-signal, that has been mixed downwards to the IF
frequency and bandwidth limited to 10 MHz.
*Parameters:
ON Bit set to 1
OFF Bit set to 0
Example:
OUTPut:IF:STATe ON
d
OUTPut
. :IF
. . [:STATe] ?
Query of IF output state
Result:
0 OFF
1 ON
Parameters:
none
Example:
OUTPut:IF:STATe? -> 1