EasyManua.ls Logo

Rohde & Schwarz PR100 - Page 169

Rohde & Schwarz PR100
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S PR100 User Manual
d
OUTPut
. :TONE
. . :THReshold <numeric_value>|UP|DOWN|MINimum|MAXimum
Setting the tone-level reference-threshold. It determines what signal level is to
be output as 400 Hz: e.g. usually this is set to 0 dBZV, which means that a
signal of that strength produces a tone of 400 Hz. Together with the settings
OUTP:TONE:GAIN, this setting determines the frequency of the tone for each
received signal level.
Parameters:
<numeric_value> level tone reference threshold in dBZV
UP|DOWN increase|decrease of level tone reference threshold by
the value set in the
OUTPut:TONE:THReshold:STEP[:INCRement]
command.
MINimum|MAXimum setting the lowest/highest level tone reference
threshold
Example:
OUTPut:TONE:THReshold 35 dBuV
d
OUTPut
. :TONE
. . :THReshold? [MINimum|MAXimum]
Query of level tone reference threshold.
Parameters:
none query of current level tone reference threshold
MINimum|MAXimum query of lowest/highest level tone reference
threshold
Result:
Level tone reference threshold in dBZV
Example:
OUTPut:TONE:THReshold? MIN -> 6

Table of Contents