7. EXPLANATION OF PARAMETERS
79
Setting practice
The following describes the procedure for selecting, for instance, 100 Hz for the position loop gain.
According to the basic operating procedure, select 3 from the Mode Select screen. Then,
1 Select page 0 using by or key.
P.UP=1,Down=0 0
Kvp = # # # # Hz
2 Using the or key, move the cursor to
the digit(s) to be modified.
3 As needed, increase or decrease the number in
each digit using the 1 or 0 key (the value
you specify will be immediately reflected in the
operation).
WR
P,Up=1,Down=0 0
Kp  =  100 Hz
4 Using the key, store your setting in the
non-volatile memory.
(Current screen data is also stored in memory if
you exit using the or / keys.)
Upon completion of the setting, the screen
shown to the right appears.
(The "Completed" message does not appear
when you use the or / keys.)
  Completed    0
Kp
 
=
 
100 Hz
5 Press the to return to the initial screen.
For setting another page, repeat the above
steps from 1.
3
01
The cursor flashes.
In order to store a modified parameter value in the non-volatile memory, you must press
either the , , or keys.
Otherwise, the modified data will not be stored.