4.6.2 CN1 & CN2 Shielding Procedure
The following figure shows the connector shielding procedure for the CN1 or CN2 connector.
There are two shielding procedures, clamp and soldering processing.
Clamp processing
1
Remove the cable sheath.
2
Mount a tape or a compression insert.
At this time, the tape or the compression
insert should be completely on the cable
sheath.
3
Fold back the drain wire.
4
Tighten the cable clamp from on the drain
wire.
Set it about 1 mm away from the end face
of the tape or the compression insert.
Set the compression insert before soldering the cable to the connector.
Tape or
compression insert
Drain wire
Sheath
φ
A
Ground plate
Drain wire
1 mm