4. WIRING
423
Soldering processing
Procedures 1 and 2 are the same as the clamp processing.
1
Turn the cable and bring the drain wire near the ground plate.
2
Applicable CN2 φ A Size
The applicable CN1 and CN2 φA sizes are shown in the following table.
Table 4-3 Applicable CN2 φ A Size
1 mm
Ground plate
Drain wire
Ground
p
lale
5 mm
Solder the drain wire
(where is narked.)
Connector No. Applicable φA size Connector model name Maker name
CN1 15.0 to 16.5 mm 10150-3000VE
10350-52A0-008
Sumitomo 3M Ltd.
CN2 10.5 to 12.0 mm 10120-3000VE
10320-52A0-008
Sumitomo 3M Ltd.