9. SPECIFICATIONS
9-6
9.1.3 Allowable Repetition Frequency
Start and stop repetition is limited by both the Servomotor and Servo Amplifier.
Consideration is required to satisfy the requirements of both at the same time.
● Allowable repetition frequency based on the Servo Amplifier
For use with a high frequency of starting and stopping, check that it is within the allowable frequency
beforehand.
The allowable repetition frequency varies with each combined motor type, capacity, load inertia,
acceleration/deceleration current value and motor speed.
When the starting/stopping repetition frequency up to the maximum speeds exceeds
times/min under "load inertia = motor inertia × m" conditions, the effective torque and regenerative
power must be accurately calculated.
In this case, consult us.
● Allowable repetition frequency based on the type of motor used
The starting/stopping frequency varies with motor working conditions including load conditions and
operating duration.
Accordingly, this cannot be specified uniformly.
In the following, typical examples will be explained.
20
m+1