7. EXPLANATION OF PARAMETERS
7-11
● Setting practice
The following describes the procedure for selecting, for instance, the velocity control for the amplifier's
control mode.
According to the basic operating procedure, select 4 from the Mode Select screen. Then,
1 Set Func6 bit7 to “1” from Mode 2 Page 7.
*
Para.
Set3
7
Func6
:
1???????
(?) appears before
the setting is down.
2 Select Mode 4.
3 Using the or key, select page 3.
*Para. Select 3
TYPE
:
4 Using the or key, scroll the screen to
select "Velocity".
WR
*
Para.
Select 3
TYPE : Velocity
5 Using the key, store your selection in the
non-volatile memory.
When the setting is completed, “Completed” is
indicated.
When you want to correct the setting, repeat the
above steps from 4.
Completed
3
TYPE
:
Velocity
6 Press the key to return to the initial screen.
For setting another page, repeat the steps from 3.
7 Turn the control power off to validate your setting (with normal parameters, you
can validate the change using the key).
4