7. EXPLANATION OF PARAMETERS
7-25
*Test 2
VCMD Not Ready
When the offset function is enabled, the OFFSET screen appears.
The screen for the torque command offset differs from that for the velocity command as
follows:
• Screen No. 2 → 3.
• VCMD → TCMD.
An ideal zero adjustment may not be expected if significant fluctuation exists in the
commanded input voltage or substantial noise is present. In such case, manual zero
adjustment shall be implemented in parallel from Screen Mode 3 Page 3 (Vzero) or 4
(Tzero).