8. MAINTENANCE
8 - 22
Table 8-2 (2/2) Troubleshooting (Non-Alarm)
No
Malfunction Inspection
Causes and corrective
measures
6 Excessive overshoot/undershoot
during start/stop
Servo tuning at “High”
Lower velocity loop gain
Increase integral time constant
Loosen acceleration /
deceleration command pattern
Use position command low pass
filter
(1) Check for mechanical
faults
Operate servomotor by itself
Check centering and balance on
coupling
7 Abnormal noise
(2) Operate at low speed
and check for random
abnormal noise
Check if sensor signal line is
pair-twisted and shielded.
Check if sensor and power lines
are connected to the same duct
Check if power supply voltage
drops

Table of Contents