9. SPECIFICATIONS
930
(2) Command pulse timing
Each command pulse timing is as follows .
Command pulse
Backward revolution
pulse train
+
Forward
revolution pulse
train.
Code + Pulse train
90° phase difference
two-phase pulse
Fig. 9-14 Command Pulse Timing
The above values apply only when screen mode 2-0 (PMOD) (digital filter DFC1 and
0 ="00", and bit 7 ="0") is selected.
t1 t2
t3 t4
t5
Backward
revolution
Forward
revolution
t1, t2 0.1 µs
t3, t4 > 750 ns
t5 > 1.5 µs
t1 t2
t3 t4
Pulse
Code
t5 t6
Forward revolution
Backward
revolution
t7 t8
t9
t1, t2 0.1 µs
t3, t4 > 750 ns
t5, t9 0.1 µs
t6, t7, t8 > 1.5 µs
t1 t2
t3 t4
t5 t6
A-phase
B-phase
Forward revolution Backward revolution
B-phase leads A-phase
by a phase angle of 90°.
A-phase leads B-phase
by a phase angle of 90°.
t1, t2 0.1 µs
t3, t4 > 750 ns
t5, t6 > 250 ns