1. BEFORE OPERATION
14
For operating safety, check that the Servo Amplifier is grounded by at least a class 3 (less than 100) of
the PE (protective earth) terminal . In addition, the grounding terminal of the Servomotor must be
connected to the PE (protective earth) terminal .
Never perform a withstand voltage or a megger test of the Servomotor or the Servo Amplifier.
In this product, 0V and the main body is earthed by the capacitor.
If such test is necessary, consult with us.
Perform correct wiring by referring to the chapter "4. Wiring".
Wrong wiring may cause Servomotor's or amplifier's breakage.
Since the "P" series Servomotor is not an induction motor, the direction of revolution cannot be changed
by swapping the phases.
To change the direction, use the remote operator.
For safety operation, be sure to install a surge absorber on the relay, electromagnetic contactor,
induction motor and brake solenoid coils.