Section 7: Replacement Procedures
CG4 Series Service Manual Page 7-21
7.15 LINERLESS (NON SEPA) LABEL SENSOR REPLACEMENT (OPTIONAL)
This section covers the basic mechanical procedures for replacement of the Linerless (Non sepa) label 
sensor.
1. Remove the Bottom Housing Cover as explained in the 
earlier 
Section 7.3 Removal of the Bottom Housing 
cover
.
2. Disconnect the Linerless (Non sepa) label sensor cable 
from the 
OPTION connector on the MAIN PCB.
3. Turn over the printer in upright position, open the Top cover 
and remove the 
Linerless (Non sepa) assembly by 
pushing it upward.
4. From the reverse side of the Linerless (Non sepa) assem-
bly
, remove the screw securing the Linerless (Non sepa) 
label sensor holder 
in place.
5. Press the tabs to release the Linerless (Non sepa) label 
sensor
 and remove the cable attached to the connector
6. Replace the new Linerless (Non sepa) label sensor and 
follow the above steps in reverse sequence, to reassemble 
the parts.
7. After replacement, perform Tear off offset position adjust-
ment. Refer to 
Section 6.6 Offset position Adjustment. 
CAUTION:
Ensure that no cables are pinched between parts when
you are installing the 
cutter kit to the printer.