Section 4: Operation and Configuration
CG4 Series Service Manual Page 4-29
4.15 FACTORY USB BOOT DOWNLOAD MODE
This mode enables the printer to connect multiple printers to a single USB port of the host computer.
In factory USB boot download mode, the printer motion will be based on the boot download mode. In this
case, the returned contents of descriptors shown below are different because serial number is not returned.
USB will be selected automatically regardless of interface you specified.
If executing auto reboot in factory USB boot download mode, the printer will be activated in factory USB
interface mode.
Notes:
If you missed the chance to release the FEED/LINE button in step 2 above, just keep holding the
FEED/LINE button and wait for the next cycle.
If you released the
FEED/LINE button at the wrong ON LINE (POWER) indicator, just turn off the power
and restart the procedure.
Descriptor type Offset Field When starting in
normal mode
When starting in this
mode
Device descriptor 16 iSerialNumber 0x03 0x00
Printer start-up
Printer statusProcedures
Off
ON LINE (POWER)
indicator
ERROR
indicator
Buzzer
One short
beep
Red light
Off
Red light
Factory Clear Mode
Two short
beeps
Off
Blinking red light
Factory Adjustment Mode
With top cover open, while
pressing the FEED/LINE
button, press and release
the POWER button.
Keep holding the
FEED/LINE button and
release it when the ON
LINE (POWER) indicator
changes to green light
and three short beep
sound is heard.
Close the top cover.
1
2
3
(The printer will cyclically
advance to next mode as
long as the FEED/LINE
button is held down.)
Factory USB Interface
Mode
Off
Green light
Three
short
beeps
Factory USB Interface
Mode
Blinking green light
(lights alternately)
Four
short
beeps
The printer will be reset
automatically and restart in
factory USB boot download
mode as soon as releasing
the FEED/LINE button.
Blinking red light
(lights alternately)