Event Messages
Definitions
All important scale functions are internally monitored,
and faults are reported by event message.
For troubleshooting details, see “ Event Messages”
item.
Message E1 Power Failure
Group code (e.g. E) and number (e.g. 1) appear in left
field of lower display.
In addition, an explanatory text can be called up.
The events are organized into 4 classes. The
assignment between event and class can be selected
using relevant parameter.
n ALARM Display is underscored and
flashes.
Red signal lamp
X flashes.
Totalization stops, scale is
inoperable.
Start:
If cause of Alarm has been
removed and error message
acknowledged.
Acknowledgement:
If cause of Alarm has not been
removed, flashing stops but
message is still on display.
n
WARNING 1 Display permanent and
underscored Totalization goes on.
Acknowledgement:
If cause of fault is still present,
underscores are faded out.
n
WARNING 2 Display permanent, not
underscored
Acknowledgement:
None
n
IGNORE No event monitoring, save
MIN/MAX messages via contact
outputs and signal lamps.
If several events occur at the same time, the most
significant event is displayed first.
Priority: Alarm, Warning 1, Warning 2
Operation
O Acknowledge events of ALARM and
WARNING 1 classes after
elimination of fault. If several events
are available, acknowledge one
after the other.
Display event texts:
G Call function distributor.
TU Scroll “Show Event” function into
lower display field.
f Select function.
0837
VBW INTECONT PLUS
Control
BV-H2214 GB 6
Technische
Redaktion PDE-RD