n
One-sided mounting of total belt
One-sided
mounting
Lg = Length up to mid hillside
2. Check Weight QPRF
Simulating a certain belt load, the check weight is
used for control of weighing system. It can act on
weighing platform direct or via lever system.
The weight to be entered into INTECONT is not the
actual weight, but the weight acting on platform.
Effective check weight QPRF is the platform load in
kg simulated by the check weight
Single-Idler Platform
a) Parallel Leaf Spring Mounting
Theoretically, the check weight can be applied
to any point of the mechanical platform
equipment. Applied weight QP is active always.
QPRF = OP
b) Joint Mounting (e.g. Universal Spring Joint):
tan(a) 0,018 · a
Angle a= 0 : K = 0
Angle a = neg : K = neg
0837