6. Characteristics
n
Power failure
Scale data, calibration values, counter readings
and pulses pending remain stored after power
failure for an unlimited period of time. The internal
clock continues running for approx. 5 days.
n
Dialog language
for error messages, operation, and service
programs.
Select: DEUTSCH
ENGLISH
FRANCAIS
ESPANOL
ITALIANO
n Units (selectable)
SI units : kg , kg/h
t , t/h
m, cm
NON-SI units: lb , lb/h
t , t/h
f , inch
(see Parameter List)
n
Start/Stop totalizing counter
Select using Parameter B06.
n
Displays
Upper display: Totalizing counter 1
Lower display: Totalizing counters 2 and 3
Feed rate absolute
Feed rate relative
Belt speed
Belt load absolute
Belt load relative
Batch data
Select for lower display using cursor keys.
n
Signal lamps (top down)
VOLTAGE OK (green)
PROCESSOR OK (green)
ALARM (red)
MIN (red) MIN feed rate value
MAX (red) MAX feed rate value
n
Event messages
Events and faults are displayed in form of an
alphanumeric code. Call clear text of consecutive
events via keyboard.
Events are organized into Alarms and Warnings,
with and without acknowledgement. Alarms stop
scale; warnings don’t.
All alarms are additionally reported via relay
output.
n Operating philosophy
Operator prompting through multi-level menus.
Important configuration and calibration functions
are protected by password.
n
Belt speed
For simple applications, speed measurement can
be omitted.
n
Zero setting
Zero setting can be performed
1- manually via keyboard
2- automatically, if belt is empty.
The maximum admissible zero setting elevation is
monitored.
0837
INTECONT PLUS VBW
Characteristics
BV-H2214 GB 29
Transmission to third parties and reproduction of
this documentation are not permitted.
SchenckProcess GmbH reserves all rights of
ownership and copyrights.
Technische
Redaktion PDE-RD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Plus Belt Weigher and is the answer not in the manual?

Schenck process Intecont Plus Belt Weigher Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Plus Belt Weigher
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals