Set Time
Unlike the other programs, date and time can be
changed in START and STOP states of scale and
read off under SERVICE VALUES.
Gf Function distributor, Calibrating
functions, password
(see “Calibrating Functions”).
TU Scroll Set Time function into lower
display field.
f Call menu.
N Abort at any time.
033 Year, e.g. 03
Enter month, day, hour, minute,
second.
f Acknowledge every input.
As soon as seconds are
acknowledged, new date is stored,
and complete date is briefly
displayed.
O Delete digit entered last
After power failure, time remains stored for min. 5
days.
Simulation Mode
The Simulation Mode lets you check all scale
functions without material at the time of
commissioning.
During simulation, scale is cannot operate in normal
mode.
Gf Function distributor, Calibration
functions, password (see
“Calibration Functions”).
TU Scroll “START Simulation” into lower
display field.
f Start program.
Display : Event message S7
In upper line, the “=” symbol
flashes.
Function can be cut off in the same way (STOP
Simulation).
Features:
1. All operating functions can be performed.
2. Feed rate actual value is set to nominal rate.
3. Belt load and speed measurement are active.
4, All control inputs/outputs operate as usually.