Printer Connectivity
Interface : Serial (see Chapter “Technical
Data”).
Character map: ISO-Latin-1 (ISO-8859-1)
Cable : The connection diagram holds
for EPSON and CITIZEN
printers.
EPSON Printer: LX 850
The interface board is equipped with 2 DIP switches
used for selection of serial message base data.
Switch
1-1 : OFF 8-bit message
1-2 : OFF No parity bit
1-3 : ON, OFF Even/odd
1-4 : OFF Positive edge
1-5...8 : OFF, ON, OFF, OFF 9600 baud
2-1...6 : ON, ON, OFF, OFF, OFF, OFF
(default)
Use Parameter J 01 to set baud rate to 9600. On the
right side of printer, there are two additional DIP
switches. Diagram view corresponds to top of printer.
Switch
1-1 : OFF Character spacing 10 CPI
1-2 : OFF Zero with no backslash
1-3 : ON Graphics character set
1-4 : OFF Auto hyphenation activated
1-5 : ON Normal print speed
1-6...8 : ON, ON, ON USA
2-1 : ON Page length 12 inch
2-2 : OFF No cut sheet
2-3 : OFF Jump over perforation
2-4 : OFF No auto line feed
Information on switch position can be printed by using
the printer self-test function. (Press line feed key while
starting printer).
CITIZEN Printer: 120D
0837
VBW INTECONT PLUS
Details
BV-H2214 GB 110
Technische
Redaktion PDE-RD
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.
Fig.: Printer Cable
Fig. EPSON Interface
Fig. EPSON Printer
Fig. Serial Interface